How Many Solar Panels to Run a Washing machine?

Sizing an array for a single appliance is the clearest way to understand solar, because it strips the question down to one load, one number of hours, and one amount of sunlight. Here is that calculation for a washing machine, with the assumptions stated so you can change them.

A washing machine drawing 500 W for 1 hours a day uses 0.50 kWh of electricity. At 4.5 peak sun hours and a 20 percent system derate, that needs about less than one standard 400 W panels, an array of roughly 0.40 kW. Fewer in Arizona, more in Seattle.

Calculate it for your own washing machine

Change any box. The result updates as you type.

W
hours
USD/kWh
Cost per month
Per hour
Per day
Per year
kWh per day
400 W panels

Planning estimate. The rate box is prefilled with a regional average; the figure on your own bill is the one that matters. Power is draw while running, not while switched on.

The arithmetic, with this appliance in it

Four steps, and none of them are difficult:

  1. Daily energy. 500 W multiplied by 1 hours, divided by 1,000, gives 0.50 kWh per day.
  2. Panel output. A 400 W panel at 4.5 peak sun hours produces 1.8 kWh on paper.
  3. Apply the derate. Inverter conversion, wiring, heat, dust and imperfect orientation take roughly 20 percent, leaving about 1.44 kWh per panel per day.
  4. Divide. 0.50 kWh divided by 1.44 kWh gives less than one panels, rounded up.

Peak sun hours is not the same as daylight hours. It is the number of hours of full-strength sun the day is equivalent to, which is why a 14-hour summer day might only count as five.

Panels needed by panel size

Larger panels mean fewer of them, not less roof area. Output per square metre has barely changed; the modules simply got bigger.

Panels needed for Washing machine at 4.5 peak sun hours
Panel ratingOutput per panel per dayPanels neededArray size
300 W1.08 kWh10.30 kW
400 W1.44 kWh10.40 kW
450 W1.62 kWh10.45 kW
500 W1.80 kWh10.50 kW
600 W2.16 kWh10.60 kW

How many panels where you live

Location changes this more than any other input. The same washing machine needs roughly twice the array in the Pacific Northwest that it needs in southern Arizona.

Panels needed by location, using 400 W panels
Peak sun hoursRoughly wherePanels neededArray size
3 hSeattle, Anchorage10.40 kW
3.5 hChicago, Boston10.40 kW
4 hNew York, Portland10.40 kW
4.5 hAtlanta, Kansas City10.40 kW
5 hDallas, Los Angeles10.40 kW
5.5 hPhoenix, Albuquerque10.40 kW
6 hSouthern Arizona, Hawaii10.40 kW

For a figure based on your actual coordinates rather than a regional band, use the location-based solar production calculator.

Panels alone will not run it

Short cycles and modest draw make this one of the easier appliances to run on solar, provided you run it in daylight.

Solar produces during the day. If the load runs when the sun is down, that energy has to come out of a battery, and the battery has to be larger than the energy it delivers because you never discharge it fully.

Battery needed to carry washing machine without sun
AutonomyEnergy requiredUsable battery at 80% depth of dischargeAt 48 V
Overnight only0.28 kWh0.35 kWh7 Ah
One full day0.56 kWh0.69 kWh14 Ah
2 days1.11 kWh1.39 kWh29 Ah
3 days1.67 kWh2.08 kWh43 Ah

Inverter sizing for a washing machine

The spin motor surges. Size for roughly 1,500 W even though running draw is 500 W.
Inverter sizing for washing machine
Running power500 W
Start-up surge1,500 W (3x running)
Minimum continuous inverter700 W
Minimum surge capability1,500 W
Current at 48 V DC11.6 A

Inverters are rated for continuous output and, separately, for a brief surge. An inverter that can run the load but not start it is a common and frustrating way to undersize a system.

Laundry is the most schedulable load in the house

Nothing about laundry has to happen at a particular time, which makes it ideal for solar. Running the machines between ten and three uses power the array is producing anyway, and on a grid-tied system that is the difference between consuming your own generation and exporting it for a lower rate.

If you have a timer or a delayed-start function, this is the appliance to use it on.

Questions people actually ask

How many solar panels does it take to run a washing machine?
About less than one standard 400 W panels, based on 500 W running for 1 hours a day and 4.5 peak sun hours. In a sunnier location it is fewer; in a cloudier one, more.
How much electricity does a washing machine use per day?
Roughly 0.50 kWh per day at 500 W for 1 hours. Change either number and the panel count changes with it.
What size inverter do I need for a washing machine?
The spin motor surges. Size for roughly 1,500 W even though running draw is 500 W. The sizing table above gives the continuous and surge figures.
Can I run a washing machine on solar without a battery?
Only while the sun is producing. A grid-tied system with no battery runs the load during daylight and draws from the grid otherwise. Off-grid, or during an outage, the battery table above is what determines whether it keeps running.

Size the whole system, not one appliance

Costs on this page use a national average residential rate of 18.44¢ per kWh (August 2026, EIA-derived state residential averages). Your own rate is printed on your electricity bill and is the number that actually matters. Every figure here is recalculated from one central rate setting, so these tables move when the national average moves.